HYDROMAX Cartridge solenoid check VALVE V3067-G03-20-S-N-D24-DG-25

V3067-G03-20-S-N-D24-DG-25 Graphic Symbol  Ordering Code V3067 -G03 -@@ -# -* -D24 -DG -25 1 2 3 4 5 6 7 8 1 V3067 Cartridge solenoid check valve V3067(10W-2) Poppet 2-Way 2 G03 G03: 3 -@@ Operation 
V3067-G03-20-S-N-D24-DG-25
Graphic Symbol 

Ordering Code

V3067 -G03 -@@ -# -* -D24 -DG -25
1 2 3 4 5 6 7 8
1 V3067 Cartridge solenoid check valve

V3067(10W-2) Poppet 2-Way

2 G03 G03:
3 -@@ Operation 
20: Normally closed one-way 21: Normally open one-way
22: normally closed two-way 23: normally open two-way
24: Sliding shaft type normally closed 25: Sliding shaft type normally open
4 -# Option:with filter
S:With Filter
N:Without Filter
5 -* Option:with manual 
N:Option
P:Push-Style Manual Override(
M:Screw-out Knob Style
Screw-in Knob Style
6 -D24 Coil Type
D12:DC12V     D24:DC24V
A24:AC24V     A11:AC110V
A22:AV220V   A38:AC380V
RA1:RAC110V RA2:RAC220V
7 -DG Terminations 
DG:DIN43650
DL:Lead Wire(2)
8 -25 Max pressure
25:bar(3550psi)

Technical Data

Max Operating pressure Rated flow Cavlity-Tooling Installation torque Weight
 bar(psi) 30(l/min) 10W-2 39-51(Nm) 0.87(kg)
Fluid-Temperatures Internal Leakage Filtration Minimum Vlotage Required
(-)20~120 ℃ 0.15cc/minute 25(um) 90% of nominal
3 drops/minute
max. at bar
No reprinting without permission:Ruhong Seiko (Xiamen) Electronics Technology Co.,Ltd. » HYDROMAX Cartridge solenoid check VALVE V3067-G03-20-S-N-D24-DG-25