Tube I.D. φ 40, 50, 63, 80, 100, 125, 150 (mm). Consider cylinder thrust force is about 70%(50% high speed) of theoretical force. Displacement is suggested about 50% of total volume.
Features:
- Consider cylinder thrust force is about 70%(50% high speed) of theoretical force.
- Displacement is suggested about 50% of total volume
- Max. oil ascending speed is about 200mm/sec
- ISO-VG32 or an equivalent oil is recommended.
- Oil is feeded not exceeding 80% of total volume.
- Unit should be installed vertically above the cylinder / actuator.
Specification:
Tube I.D. (mm) | 40, 50, 63, 80, 100, 125, 150 |
---|---|
Medium | ISO VG32 EQUIVALENT |
Operating pressure range | 0.05~1 MPa |
Proof pressure | 1.5 MPa |
Ambient temperature | -5~+60℃ (No freezing) |
Available speed range | 50~500 mm/sec |