Fixed Orifice, Bypass/Restrictive, Pressure Compensated Priority Flow Control Valve
TECHNICAL DATA
- Max. Operating pressure: 350 bar
- Maximum Inlet Flow : 240 l/min
- riority Flow Ranges: 0.8-95 l/min
- Cavity-Tooling: 17A-3
- Installation torque: 200-215 Nm
- Weight: 0.57(Z=L) kg
- Pressure at the bypass port(port 2) may exceed pressure at the priority port (port 3)
- Both priority and bypass flow are usable up to the system operating pressure
- Bypass flow is not available until priority flow requirements are satisfied
- Blocking priority flow will also block bypass flow
- If a momentary impact pressure is needed in the application, please consult our sales department.
FR17A3F0040N | FR17A3F0040L | FR17A3F0040K |
FR17A3F0076N | FR17A3F0076L | FR17A3F0076K |
FR17A3F0250N | FR17A3F0250L | FR17A3F0250K |
FR17A3F0260N | FR17A3F0260L | FR17A3F0260K |
FR17A3F0300N | FR17A3F0300L | FR17A3F0300K |
FR17A3F0450N | FR17A3F0450L | FR17A3F0450K |
FR17A3F0600N | FR17A3F0600L | FR17A3F0600K |
FR17A3F0650N | FR17A3F0650L | FR17A3F0650K |