Without Pilot Assist,3 Port Cavity Counterbalance Valve
TECHNICAL DATA
- Max. Setting: 280 bar
- Rated flow: 120 l/min
- Cavity-Tooling: 2A-3
- Installation torque: 60-70 Nm
- Weight: 0.29 kg
Pressure Setting:
- Setting should be 1.3 times maximum
- load induced pressure.
- (We suggest when the Max. setting pressure is 280 bar, the load pressure has to be lower than 215 bar.)
CB2A23HL | CB2A23HC |
CB2A23IL | CB2A23IC |
CB2A23AL | CB2A23AC |
CB2A23BL | CB2A23BC |
CB2A23EL | CB2A23EC |