HYDROMAX Cartridge solenoid check VALVE V2067-G02-20-S-N-D24-DG-25

V2067-G02-20-S-N-D24-DG-25 Graphic Symbol  Ordering Code V2067 -G02 -@@ -# -* -D24 -DG -25 1 2 3 4 5 6 7 8 1 V2067 Cartridge solenoid check valve V2067(08W-2) Poppet 2-Way 2 G02 G02: 3 -@@ Operation 
V2067-G02-20-S-N-D24-DG-25
Graphic Symbol 

Ordering Code

V2067 -G02 -@@ -# -* -D24 -DG -25
1 2 3 4 5 6 7 8
1 V2067 Cartridge solenoid check valve

V2067(08W-2) Poppet 2-Way

2 G02 G02:
3 -@@ Operation 
20: normally closed one way
21: Normally open one way
22: normally closed two-way
23: Normally open two-way
24: Sliding shaft type normally closed
25: Sliding shaft type normally open
4 -# Option:with filter
S:With Filter
N:Without Filter
5 -* Option:with manual 
N:Option
P:Push-Style Manual Override
M:Screw-out Knob Style
Screw-in Knob Style
6 -D24 Coil Type
D12:DC12V     D24:DC24V
A24:AC24V     A11:AC110V
A22:AV220V   A38:AC380V
RA1:RAC110V RA2:RAC220V
7 -DG Terminations 
DG:DIN43650
DL:Lead Wire(2)
8 -25 Max pressure 
25:bar(3550psi)

Technical Data

Max Operating pressure Rated flow Cavlity-Tooling Installation torque Weight
 bar(psi) 15(l/min) 08W-2 39-51(Nm) 0.69(kg)
Fluid-Temperatures Internal Leakage Filtration Minimum Vlotage Required
(-)20~120 ℃ 0.15cc/minute 25(um) 90% of nominal
3 drops/minute
max. at bar

Cavity-Tooling
V2066(04)成型孔