Without Pilot Assist,3 Port Cavity COUNTERBALANCE VALVE.
TECHNICAL DATA
- Max. Setting: 350 bar
- Rated flow: 60 l/min
- Cavity-Tooling: 11A-3
- Installation torque: 40-50 Nm
- Weight: 0.15 (Z=L) kg
Pressure Setting:
- Setting should be 1.3 times maximum oad induced pressure.
- (We suggest when the Max. setting pressure is 350 bar, the load pressure has to be lower than 270 bar.)
CB11A23HL | CB11A23HC |
CB11A23IL | CB11A23IC |
CB11A23AL | CB11A23AC |
CB11A23BL | CB11A23BC |
CB11A23EL | CB11A23EC |
CB11A23CL | CB11A23CC |