TAIWAN WINNER CA2A SERIES COUNTERBALANCE VALVE

Vented, Atmospherically Referenced, 280 Bar Maximum Setting Counterbalance Valve TECHNICAL DATA Max. Operating pressure: 280 bar Rated flow: 120 l/min Cavity-Tooling: 2A-3 Installation torque: 60-70 N

Vented, Atmospherically Referenced, 280 Bar Maximum Setting Counterbalance Valve

TECHNICAL DATA

  • Max. Operating pressure: 280 bar
  • Rated flow: 120 l/min
  • Cavity-Tooling: 2A-3
  • Installation torque: 60-70 Nm
  • Weight: 0.36 kg
  • Pressure Setting:
    Setting should be 1.3 times maximumload induced pressure.(We suggest when the Max. setting pressure is 280 bar, the load pressure has to be lower than 215 bar.)
  • Approximately 1 drop (0.07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.

CA2A3AHL CA2A3AHC
CA2A3AIL CA2A3AIC
CA2A3CHL CA2A3CHC
CA2A3CIL CA2A3CIC
No reprinting without permission:Ruhong Seiko (Xiamen) Electronics Technology Co.,Ltd. » TAIWAN WINNER CA2A SERIES COUNTERBALANCE VALVE