TAIWAN WINNER CA19A SERIES COUNTERBALANCE VALVE

Vented, Atmospherically Referenced, 280 Bar Maximum Setting Counterbalance Valve TECHNICAL DATA Max. Operating pressure: 280 bar Rated flow: 480 l/min Cavity-Tooling: 19A-3 Installation torque: 465-50

Vented, Atmospherically Referenced, 280 Bar Maximum Setting Counterbalance Valve

TECHNICAL DATA

  • Max. Operating pressure: 280 bar
  • Rated flow: 480 l/min
  • Cavity-Tooling: 19A-3
  • Installation torque: 465-500 Nm
  • Weight: 1.62 kg
  • Pressure Setting:
    Setting should be 1.3 times maximumload induced pressure.(We suggest when the Max. setting pressure is 280 bar, the load pressure has to be lower than 215 bar.)
  • Approximately 1 drop (0.07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.

CA19A3AHL CA19A3AHC
CA19A3AIL CA19A3AIC
CA19A3CHL CA19A3CHC
CA19A3CIL CA19A3CIC