Vented, Atmospherically Referenced, 280 Bar Maximum Setting Counterbalance Valve
TECHNICAL DATA
- Max. Operating pressure: 280 bar
- Rated flow: 240 l/min
- Cavity-Tooling: 17A-3
- Installation torque: 200-215 Nm
- Weight: 0.74 kg
- Pressure Setting:
Setting should be 1.3 times maximumload induced pressure.(We suggest when the Max. setting pressure is 280 bar, the load pressure has to be lower than 215 bar.) - Approximately 1 drop (0.07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
CA17A3AHL | CA17A3AHC |
CA17A3AIL | CA17A3AIC |
CA17A3CHL | CA17A3CHC |
CA17A3CIL | CA17A3CIC |